Wind Load Calculation per ASCE 7: Velocity Pressure, Gust Factor and Design Wind Pressure Worked Example
Wind often governs lateral design and roof uplift on steel industrial buildings, yet the ASCE 7 procedure is easy to misapply when editions mix. This post answers three common questions, then works an example for a steel-frame building. It extends our overview of structural engineering for industrial plants . Steel-frame building under construction. Photo: Dwight Burdette, CC BY 3.0, via Wikimedia Commons . What is the formula for calculating wind load? For a building, the design wind pressure on a surface is p = q G Cp − qi (GCpi), and the force is F = p × A, where A is the tributary area. The velocity pressure follows from wind velocity: qz = 0.00256 Kz Kzt Kd Ke V² in psf with V in mph, or qz = 0.613 Kz Kzt Kd Ke V² in N/m² with V in m/s. Kz is the height exposure coefficient, Kzt the topographic factor, Kd the wind directionality factor, Ke the ground elevation factor (ASCE 7-16 onward), G the gust factor (0.85 for rigid buildings) and Cp the external pressure coefficient. Th...