Flange Pressure-Temperature Rating per ASME B16.5: Class Selection, Material Groups and Worked Example
- Get link
- X
- Other Apps
Choosing the wrong flange class is expensive: too low and the joint is under-rated at temperature, too high and cost, weight and bolting grow for no benefit. This post answers five common questions on ASME B16.5 ratings, then selects a class for a carbon steel worked case. Values quoted are for illustration; confirm them against the current edition of the standard.

What is the pressure rating of a 150 lb flange at ambient temperature?
In ASME B16.5, a Class 150 flange in Group 1.1 carbon steel (A105 forgings, A216 WCB castings) is rated 19.6 bar (285 psig) at the 38°C (100°F) reference temperature. The "150 lb" label is a pressure class, not a pressure in pounds, and the rating falls as temperature rises, to 10.2 bar at 300°C.
The standard covers steel flanges and flanged fittings from NPS ½ to 24. Cast iron flanges belong to ASME B16.1, with different ratings, and threaded fittings have their own standards; B16.5 includes only the threaded flange. Valves with flanged ends take their flange dimensions from B16.5, but the valve body rating comes from ASME B16.34.
Class 300 flange dimensions differ from Class 150: a larger outside diameter, a thicker flange and often more or larger bolts, so the two classes do not interchange. Flanges must withstand a shell hydrostatic test at 1.5 times the 38°C rating.
Is it ASME B16.5 or ANSI B16.5?
Both names refer to the same standard. It began as ANSI B16.5, and it is now published by ASME, with ANSI approving it as an American National Standard, so current documents cite ASME B16.5. It defines steel pipe flange types: weld neck (WN), slip-on, socket weld, threaded, lap joint and blind. A slip-on and a weld neck flange of the same class share a rating, but the weld neck's tapered hub gives better stress transfer to the pipe.
European practice is separate: EN 1092-1 uses PN ratings, and older DIN flanges follow metric bolt circles and thicknesses. A 150 flange and a PN 16 flange can look alike but should not be mated without a specific engineering check.
What are the pressure-temperature ratings for flanges?
ASME B16.5 lists the maximum allowable working pressure of each class at each temperature, with one table per material group. Group 1.1 (Table 2-1.1) covers common carbon steels such as A105; stainless steels sit in Groups 2.1 and 2.2 and generally have lower ambient ratings. The classes are 150, 300, 400, 600, 900, 1500 and 2500. Group 1.1 values in bar:
| Temperature (°C) | Class 150 | Class 300 | Class 600 |
|---|---|---|---|
| 38 | 19.6 | 51.1 | 102.1 |
| 100 | 17.7 | 46.6 | 93.2 |
| 200 | 13.8 | 43.8 | 87.6 |
| 300 | 10.2 | 39.8 | 79.6 |
| 400 | 6.5 | 34.7 | 69.4 |
Class 150 retains only about a third of its ambient rating at 400°C, while Class 300 keeps about two thirds, so temperature matters as much as the class number. Flange markings carry the manufacturer, size, class and material grade, so the markings tell you which class and table apply. Ratings apply to the flange; a ball valve or other component in the same line may be limited by its own body rating or soft seats, and the lowest-rated item governs piping.

How to calculate flange rating?
You do not calculate a rating; you look it up and compare it with the design condition. The sequence is:
- Find the material group from the specification (A105 is Group 1.1).
- Take the design pressure and its coincident design temperature.
- Read each class at that temperature, interpolating linearly between listed temperatures but never between classes.
- Select the lowest class whose rating is at least the design pressure.
- Check the planned hydrotest and any upset conditions against the flange.
For NPS 26 to 60, use ASME B16.47 (Series A or B), which has its own dimensions and tables. The pipe wall is a separate check, covered in our ASME B31.3 pipe wall thickness post, because flange class does not set the pipe pressure design.
Geometry such as the pipe flange PCD (bolt circle diameter) and bolt count comes from the dimension tables and does not change the rating. To calculate bolt length, add two flange thicknesses, the gasket, two nut heights and about two threads of projection at each end, then confirm with bolting charts. A rating also does not prove the joint is tight; that depends on bolt load and pipe loads, as in our flange leakage check post.
What is the pressure rating for a 600 lb ANSI flange?
For Class 600 in Group 1.1, B16.5 gives 102.1 bar (1,480 psig) at 38°C, 93.2 bar at 100°C, 79.6 bar at 300°C and 69.4 bar at 400°C, roughly twice the Class 300 values. Class 600 has a 6.4 mm raised face added to the flange thickness, while the 1.6 mm face on Class 150 and 300 is included, which matters for stud length. Valves and fittings in Class 600 carry their own B16.34 or B16.5 rating, so confirm dimensions and temperature limits for each; sizes above NPS 24 follow B16.47.
Worked Example: Selecting a Class for 32 barg at 320°C
A carbon steel process line (A105 weld neck flanges, Group 1.1) has a design pressure of 32 barg at a coincident design temperature of 320°C. The line is hydrotested at ambient temperature.
| Step | Calculation | Result |
|---|---|---|
| Class 150 at 320°C | 10.2 − (20/25) × (10.2 − 9.3) | 9.5 bar, below 32 (reject) |
| Class 300 at 320°C | 39.8 − (20/25) × (39.8 − 38.7) | 38.9 bar, above 32 (accept) |
| Margin | 38.9 − 32 | 6.9 bar (22% of design) |
| Test pressure | 1.5 × 32 (ST/S ≈ 1) | 48 bar; ambient rating 51.1 bar |
| Shell test limit | 1.5 × 51.1 | 76.7 bar, rounded up to 77 bar |
Class 300 is selected. Class 150 falls far short, and Class 600 would add weight and cost without need. Class 300 dimensions and bolting then follow from B16.5. Pressure at the flange also depends on line losses; see our pipe pressure drop calculation post. The test pressure is below the ambient rating, so no special test limit applies.
Practical Checks
- Use the pressure and temperature that occur together, and check upset and start-up cases too.
- Confirm the material group; a low-temperature or alloy grade can sit in another group with different ratings.
- Check valves, instruments and equipment nozzles in the line; the lowest rating governs.
- Match gasket, studs and nuts to the class and temperature, and keep facing types consistent across the joint.
- Include flanged joints in the stress model; our CAESAR II load cases post gives templates for the cases a leakage check needs.
- Record the code edition on the line list and flange datasheet, because ratings can change between editions.
How Fluxiss Approaches Flange Rating
Fluxiss is a multidisciplinary engineering consultancy serving oil and gas, power and maritime clients. Its piping team sets flange classes from the line list, material specification and design conditions, then carries the joints into the stress analysis so the rating, loads and leakage checks agree.
Frequently Asked Questions
Can I use a higher class than required?
Yes, but weight, cost and bolting rise, and the mating valves and nozzles must match.
Can I interpolate between classes?
No. Interpolate only between listed temperatures within one class.
Does the class rating include pipe loads?
No. It covers pressure and temperature only; external loads need a separate flange check.
Is a Class 300 valve always rated like a Class 300 flange?
Not always; check the valve standard, trim and seat limits as well as the flange table.
Need help with flange selection and pipe stress analysis?
Fluxiss provides piping and stress analysis for process, power and marine piping, including flange class selection, load cases and flange leakage checks. Send your line list and design conditions, and the team can advise on the checks you need.
- Get link
- X
- Other Apps
Comments
Post a Comment
Questions or corrections are welcome. Please mention the relevant section and units. Do not post confidential project data or personal contact details. For project inquiries, use the Fluxiss contact page.