Lifting Lug Design Calculation: Pin Hole Bearing, Tear-Out, Weld Check and SWL Worked Example
A lifting lug carries the full weight of a vessel or tank during erection, so its calculation must cover the pin, the plate, the weld and the shell it is attached to. This post answers four common questions on lifting lug design calculation, then works an example in SI units. Allowable stresses and geometry are assumed for illustration; confirm against the governing code, project specification and rigging data.

How to calculate lifting lugs?
Start with the lift data: the lifted weight W (including attachments and rigging), the centre of gravity, the number of lugs n and the sling angle θ from horizontal. The design load per lug is P = W × DAF / (n × sin θ), where DAF is the dynamic factor. Sling angle matters: lower angles raise the lug load and the horizontal force on the lug. Then check the lug plate for pin bearing, net section tension and tear-out, check the lug weld, and check the shell or any pad at the lug. Many engineers keep these checks in a calculation Excel sheet so every lug case repeats the same lug analysis.
The shell is often the weak point. Local stress from the lug load can be checked with the method in our pipe shoe and trunnion local stress post (WRC 107/297), and a doubler plate can follow our reinforcement pad design post. Use finite element analysis when the shell is thin, the lug is large or the load path is unusual. Out-of-plane load, commonly taken as about 5% of the lug load, should also be checked; confirm against the project specification.
How to calculate lug size?
Size the plate from the pin outward. First choose the shackle and take its pin or bolt diameter d and jaw width from the manufacturer's data. The hole diameter is the pin diameter plus a small clearance, commonly 2 to 3 mm, because a loose fit raises bearing stress. Then:
- Thickness for bearing: t = P / (d × 0.9 Fy).
- Radius for tear-out: R = dh/2 + P / (2 × t × 0.4 Fy).
- Net section check: σt = P / [t (2R − dh)] ≤ 0.6 Fy.
- Lug thickness, including any cheek plates, must fit inside the shackle jaw width.
These allowables follow AISC ASD logic; ASME BTH-1 uses design categories and service factors, so apply whichever your project specifies. Use the erection weight, which differs from the operating weight used for the shell in our pressure vessel shell thickness post and for supports in our saddle support design post.

What is the lifting formula?
For rigging design the lifting formula is the design load F = W × g × DAF, where W is mass, g = 9.81 m/s² and DAF is the dynamic amplification (impact) coefficient. Onshore vessel lifts commonly use about 1.5 or a value from the project lifting specification, while offshore and marine lifts use higher, motion-based values. Add the weight of slings, shackles and any spreader beam to the hook load, and allow for centre of gravity uncertainty. Each lug then takes F divided by the number of lugs and the sine of the sling angle. The NIOSH lifting equation and its lifting index apply to manual handling, not to crane rigging design.
How to calculate SWL for lifting?
SWL (now more often called WLL, working load limit) is the maximum load a piece of equipment may carry, taken from its tag or datasheet. You do not calculate it for catalogue items; you calculate the load on each item and compare. For a two-leg bridle at angle θ from horizontal, leg tension is T = W / (2 sin θ), so capacity falls as the legs flatten: at 30° the bridle carries no more than one vertical leg's WLL.
Compare T with the WLL of the wire rope or chain sling at that angle: wire rope WLL is typically breaking force divided by a design factor of 5, and chain sling capacity is rated by grade and size on its tag. A lifting beam (spreader beam) makes the legs vertical and removes the horizontal squeeze on the lugs, but the beam itself needs design. Finally, the crane SWL, read from the load chart at working radius, must exceed the total hook load.
Worked Example: Two-Lug Lift of a 25 t Vessel
Assumptions: erection weight 25,000 kg, two lugs, 60° sling angle from horizontal, DAF 1.5, plate Fy = 260 MPa, E70 fillet weld (allowable 0.3 × 482 = 145 MPa), 45 mm shackle pin, 48 mm hole, plate 25 mm thick, R = 70 mm, base length 250 mm welded both sides with 12 mm fillets, load line 120 mm above the base.
| Step | Calculation | Result |
|---|---|---|
| Design load | 25,000 × 9.81 × 1.5 | 367.9 kN |
| Vertical per lug | 367.9 / 2 | 184.0 kN |
| Lug load P (along sling) | 184.0 / sin 60° | 212.4 kN |
| Required thickness | 212,400 / (45 × 0.9 × 260) | 20.2 mm, use 25 |
| Required radius | 24 + 212,400 / (2 × 25 × 104) | 64.9 mm, use 70 |
| Bearing stress | 212,400 / (45 × 25) | 188.8 MPa ≤ 234 |
| Net tension | 212,400 / [25 × (140 − 48)] | 92.3 MPa ≤ 156 |
| Tear-out shear | 212,400 / (2 × 25 × 46) | 92.3 MPa ≤ 104 |
| Weld tension (direct + bending) | 368 + 612 | 980 N/mm |
| Weld shear | 106,200 / 500 | 212 N/mm |
| Weld stress | √(980² + 212²) / (0.707 × 12) | 118 MPa ≤ 145 |
| Sling leg load | 245.3 / (2 × sin 60°) × 1.5 | 212.4 kN (21.7 t) |
All lug checks pass, with tear-out the tightest at 89% of allowable (92.3 / 104). Rigging legs and shackles are selected for 21.7 t where the project applies DAF to rigging (14.4 t static), so a shackle of at least 25 t WLL and a matching sling would be chosen from manufacturer data. The shell still needs a local stress check at the lug, which this example omits, and the lug should be checked for out-of-plane load.
Practical Checks
- Use the erection weight with a contingency for attachments and rigging, and verify the centre of gravity first.
- Align the lug plane with the sling direction, or design for the actual load direction.
- Use double fillet or full-penetration welds, wrap returns at the ends, and inspect by MT or PT before the lift.
- Choose lug steel with suitable toughness for the lowest temperature, and keep lug welds clear of shell seams.
- Check the welding sequence: lugs on a vessel needing post-weld heat treatment are normally welded before it and need compatible material.
- Mark each lug with its rated load, and keep the calculation and inspection records.
How Fluxiss Approaches Lifting Lugs
Fluxiss is a multidisciplinary engineering consultancy serving oil and gas, power and maritime clients. Its vessel team sizes lifting lugs together with shell local stress, supports and the lift plan, so the rigging and the pressure part are checked as one.
FAQ
Is SWL the same as WLL?
Practically yes; WLL is the current term, while SWL still appears on older equipment and crane charts.
Should I use a spreader beam?
Use one when sling angles are low or lug horizontal loads are unacceptable; it keeps the legs vertical.
What DAF should I use?
Use the value in the project lifting specification; 1.5 is common onshore, but offshore lifts differ.
Do I need FEA for every lug?
No. Hand calculations suit simple plate lugs; use FEA for thin shells, large loads or unusual geometry.
Need help with lifting lugs and pressure vessel design?
Fluxiss provides pressure vessel design for process and power plants, including lifting lug calculations, local stress checks and support design. Send your vessel data and lift plan, and the team can advise on the checks you need.
Comments
Post a Comment
Questions or corrections are welcome. Please mention the relevant section and units. Do not post confidential project data or personal contact details. For project inquiries, use the Fluxiss contact page.