Pressure Relief Valve Sizing Calculation: API 520 Worked Example
- Get link
- X
- Other Apps
Pressure relief valve sizing decides whether a vessel or pipeline survives an overpressure event, so the required orifice area must be calculated from the governing scenario, not guessed. This post covers the API 520 gas and liquid area equations, the 3% inlet loss rule, how Cv differs from relief sizing, and a gas-case worked example with API 526 orifice selection.

How to size pressure relief valves?
Work through the scenario first, then the hardware. Identify the governing overpressure case (blocked outlet, control failure, fire, thermal expansion), the required relieving rate, the fluid phase, the set pressure and the allowable overpressure. Calculate the required effective area, then pick the next larger standard orifice from the API 526 letter series; this table of areas is the usual PSV sizing chart. A PSV is the generic term for a pressure safety valve: a safety valve pops open on gas or steam, a relief valve opens in proportion on liquid, and a pilot operated relief valve uses system pressure on a pilot to hold the main disc shut, allowing operation closer to set pressure and higher backpressure. A regulating valve controls normal pressure but is not a protective device; its failure open is often the scenario the PSV must handle.
Set Pressure, Overpressure and Correction Factors
Set pressure is the inlet pressure at which the valve starts to open and must not exceed the MAWP established in our pressure vessel shell thickness calculation. Overpressure is the rise above set pressure; accumulation is the rise above MAWP. For a single non-fire case the usual limit is 10% (ASME VIII UG-125), 16% for multiple valves and 21% for fire. Relieving pressure is P1 = set × (1 + overpressure) + atmospheric. Correction factors in the area equations are Kd (discharge coefficient, typically 0.975 for gas and 0.65 for liquid), Kb (backpressure, 1.0 for conventional valves with low backpressure), Kc (0.9 with an upstream rupture disk, otherwise 1.0) and Kw (backpressure for balanced bellows on liquid). Values are illustrative; confirm in API 520.
How to calculate PSV sizing?
Start with the required relieving rate W for each scenario and size for the largest. For the fire case, API 521 gives heat input Q = 21,000 F Aws0.82 Btu/h (Aws wetted area in ft², F environment factor, for adequate drainage and firefighting), and W = Q / latent heat. For gas or vapour at critical flow, API 520 Part I gives (US units, A in in², W in lb/h, P1 in psia, T in °R):
- Gas/vapour: A = W / (C Kd P1 Kb Kc) × √(T Z / M), with C = 520 √(k [2/(k+1)](k+1)/(k−1))
- Liquid: A = Q / (38 Kd Kw Kc Kv) × √(G / (P1 − P2)), with Q in gpm and pressures in psig
- Two-phase flow: A = W / (G Kd Kb Kc), with mass flux G from the omega method
Use a calculation sheet or Excel calculation sheet for each scenario, listing inputs, factors and the selected orifice, and hand-check it against one case like the example below. In SI, the gas form is unchanged with W in kg/h, P1 in kPa abs, T in K, A in mm² and C = 0.03948 √(k [2/(k+1)](k+1)/(k−1)).

Worked Example: Gas Case and API 526 Orifice Selection
Assumptions: a vessel with MAWP 150 psig (10.3 barg) and set pressure equal to MAWP is protected by a conventional spring valve on a blocked-outlet case. Relieving rate W = 20,000 lb/h (9,072 kg/h) of hydrocarbon vapour with M = 30, k = 1.3, Z = 1.0 and T = 560 °R (311 K). Overpressure is 10%, backpressure is low (Kb = 1.0), no rupture disk (Kc = 1.0) and Kd = 0.975.
| Step | Calculation | Result (US / SI) |
|---|---|---|
| Relieving pressure | 150 × 1.10 + 14.7 | P1 = 179.7 psia (1,239 kPa abs) |
| Coefficient C | 520 √(1.3 × 0.3425) | C = 347 |
| Temperature factor | √(560 × 1.0 / 30) | 4.32 |
| Required area | 20,000 × 4.32 / (347 × 0.975 × 179.7) | A = 1.42 in² (917 mm²) |
| Orifice selection | API 526 J = 1.287 in² (too small), K = 1.838 in² | Select K (1,186 mm²) |
| Utilisation | 1.42 / 1.838 | 77% |
| Rated capacity at K | 20,000 × 1.838 / 1.42 | about 25,900 lb/h (11,700 kg/h) |
The J orifice offers only 1.287 in², below the 1.42 in² required, so the K orifice is selected at 77% utilisation. Orifice areas are recalled from API 526 for illustration; confirm against the datasheet.
What is the 3% rule for pressure relief valves?
The 3% rule limits the non-recoverable pressure loss in the inlet piping between the protected vessel and the PSV inlet to 3% of the valve set pressure, calculated at rated flow. If the inlet loss exceeds the valve blowdown, the valve opens, inlet pressure drops, the disc recloses and the valve chatters, which damages the seat. For a 150 psig set pressure, the limit is 4.5 psi.
For valve installation, calculate the inlet line with the Darcy method in our pipe pressure drop calculation post, keep it short and at least as large as the valve inlet, and avoid block valves unless locked open. If the loss exceeds 3%, shorten or enlarge the line, or use a pilot operated valve with remote sensing. A PSV is not a pressure regulator: a regulator holds normal pressure, while the valve set pressure should sit about 10% above operating pressure, and the 3% limit applies equally to fire protection duty.
How to calculate Cv with GPM?
For liquids, the flow coefficient is Cv = Q √(G / ΔP), where Q is the valve flow rate in gpm, G is specific gravity and ΔP is the pressure drop in psi. Cv is the gpm of 60°F water that passes at 1 psi drop, so 100 gpm of water at a 25 psi drop gives a valve Cv value of 100 × √(1/25) = 20. For gases, use mass flow or standard gas flow with an expansion factor, because gas flow chokes at high pressure drop; follow ANSI/ISA-75.01 or the vendor's sizing method.
Control valve sizing and relief valve sizing differ: a control valve throttles at a calculated pressure drop within its stroke, while a relief valve must pass full rated flow at fixed lift and is sized by effective area. For liquid relief the two are linked, since the area equation reduces to Cv ≈ 38 Kd A; a K orifice at Kd = 0.65 behaves like Cv ≈ 45. Use a control valve's maximum Cv to find the relieving mass flow for a failure-open case, not to size the PSV orifice.
Practical Checks
- Size for the governing scenario and check every other case against the same orifice.
- Check outlet piping and built-up backpressure, and use bellows or pilot operated valves when it is high.
- Confirm set pressure does not exceed MAWP, and that the hydrotest in our hydrostatic test pressure calculation uses the same MAWP.
- Do not forget discharge reaction force, noise and thermal relief for blocked-in liquid lines.
- Use consistent units and absolute pressure in the gas equation; mixing psig and psia is a common error.
How Fluxiss Approaches Relief Valve Sizing
Fluxiss is a multidisciplinary engineering consultancy serving oil and gas, power and maritime clients; its pressure vessel team ties relief scenarios, set pressure and MAWP together so that the valve, the vessel and the piping are checked as one system.
Frequently Asked Questions
Is a PSV the same as a safety valve?
Often used interchangeably; strictly, a safety valve is for gas or steam, a relief valve for liquid.
Can I size a PSV from the vessel volume?
No. Size it from the required relieving rate of the governing scenario.
Why use absolute pressure in the gas equation?
Gas density depends on absolute pressure, so P1 must include atmospheric pressure.
What if the calculated area falls between two orifices?
Select the next larger standard orifice.